Microstructure Testing Machine: Sample Prep and Hardness Mapping
What a Microstructure Testing Machine Actually Does
A microstructure testing machine is not a single instrument but a linked workflow: a metallographic preparation line that turns a cut section into a flat, scratch-free surface, an indentation system that measures local hardness, and a stage or software layer that records where each measurement was taken. The value of the workflow lies in repeatability. Two operators preparing the same sample should reach the same surface finish, and two hardness runs on the same sample should return the same map.
Preparation is where most variation enters. Cutting introduces deformation, grinding removes it, and polishing must not create a new damaged layer. Hot mounting embeds a specimen in thermosetting resin at about 150-180 C under pressure, which protects edges and holds small parts square to the indenter. Edge retention matters because hardness near a carburized case or a weld toe is often the number the engineer actually wants.
Hardness mapping then converts a prepared surface into a field of values rather than a single reading. The indenter steps across a grid, and each point is logged with its coordinates so gradients can be plotted. For the preparation and indentation hardware, see our metallographic hardness testing range, which covers mounting, polishing and hardness measurement in one line.
CHENJI builds these systems alongside its broader material testing programme, so a laboratory can keep preparation, hardness and mechanical testing under one supplier and one calibration schedule. That matters when results from different benches must be compared.
Standards, Materials and What the Numbers Mean
Hardness results are only meaningful when the method is named. ISO 6507-1 covers Vickers hardness testing and ISO 6508-1 covers Rockwell hardness testing; ASTM E18 covers Rockwell hardness testing of metallic materials and ASTM E10 covers Brinell hardness testing. Rockwell HRC testing uses a diamond cone indenter with a 150 kgf total test force and a 10 kgf preload. Quote the scale, the force and the standard together, or the number cannot be reproduced elsewhere.
Preparing Surfaces That Survive Indentation
Metallographic polishing sequences commonly use diamond suspensions from 9 um down to 0.25 um, finished with 0.05 um colloidal silica. Each step must remove the damage of the previous one; skipping a grade leaves scratches that show up as scatter in the hardness map. For soft or coated samples, the final silica stage also helps reveal grain structure without etching.
Mechanical test data follow the same discipline. ISO 6892-1 covers tensile testing of metallic materials at room temperature, with ASTM E8/E8M as the US equivalent, and GB/T 228.1 covers the tensile test of metallic materials at room temperature. Impact toughness is governed by ISO 148-1, with ASTM E23 as the US equivalent, on a standard Charpy specimen of 10 mm x 10 mm x 55 mm with a 2 mm deep V notch. Hardness maps are usually read alongside these results, so the metal testing instruments on the same bench should share a calibration calendar.
Force measurement underpins all of it. ISO 7500-1 covers verification and calibration of the force measuring system of uniaxial testing machines, and ASTM E4 covers the practice for force verification of testing machines. Load cells are commonly supplied as class 0.5 or class 1 per ISO 7500-1, meaning the indicated force stays within +/-0.5 % or +/-1 % of the true force. Calibration certificates are normally issued for 12 months and should be traceable to national force standards.
Equipment Selection and Mapping Method
Capacity selection follows the specimen and the standard, not the other way round. A 1000 kN machine is not suitable for a sample that needs 1 N of force. Single-column universal testing machines are typically used from about 100 N to 5 kN, dual-column machines commonly cover 5 kN to 600 kN, and hydraulic frames are used above 600 kN, with universal testing machine capacities commonly ranging from 5 kN to 3000 kN. Use the UTM capacity selector before specifying a frame for any test that will run beside the hardness bench.
For the hardness map itself, define the grid before the first indentation. Spacing must exceed the indentation diameter and the affected zone, especially on small parts, and the pattern should follow the feature of interest: a case depth profile, a weld traverse or a heat-affected band. Record the standard, the scale, the force and the dwell so the map can be repeated.
| Task | Typical equipment | Standard reference |
|---|---|---|
| Mounting and polishing | Hot mounting press, diamond suspensions 9 um to 0.25 um, 0.05 um silica finish | ISO 6507-1 / ISO 6508-1 |
| Hardness mapping | Vickers or Rockwell system with motorized stage | ISO 6507-1, ISO 6508-1, ASTM E18 |
| Cross-check tensile | Dual-column UTM, class 0.5 or class 1 load cell | ISO 6892-1, ASTM E8/E8M |
Cross-checks keep the map honest. A tensile test on the same heat, run at a crosshead speed from about 0.01 mm/min up to 500 mm/min on a servo controlled frame, confirms that the hardness trend matches strength. For elevated temperature work, split tube furnaces commonly cover 100 C to 1200 C, and high temperature versions reach 1600 C, under ISO 6892-2 or ASTM E21. Related benches for fasteners and springs are listed under fastener testing applications.
FAQ
Which Rockwell force should I use for a carburized case?
Use the scale that keeps the indentation within the case; HRC applies a 150 kgf total force with a 10 kgf preload under ISO 6508-1. Convert to Vickers per ISO 6507-1 when the case is thin.
How do I keep a hardness map comparable between two laboratories?
Quote the standard, the scale, the test force, the dwell and the grid spacing with every map. Results are only comparable when they are quoted with the standard, the specimen geometry, the test speed and the force measurement class.
Does the polishing sequence change the measured hardness?
Yes, if damage is left behind. A sequence from 9 um diamond down to 0.25 um, finished with 0.05 um colloidal silica, removes prior deformation so the indenter reads the true structure rather than a smeared layer.
Closing Notes
Build the map around the feature you need to prove, then choose preparation depth, indentation spacing and cross-check tests to match it. CHENJI supplies preparation, hardness and mechanical testing equipment from chenjitester.com, with calibration traceable to national force standards. Email annie@chenjitester.com or call +86 158 5311 1612, or Request a Quote for a configured line. See also our spring testing systems and automotive test benches for related work.